Rinnai RHFE-1004FA Instrukcja Instalacji

Przeglądaj online lub pobierz Instrukcja Instalacji dla Nie Rinnai RHFE-1004FA. Rinnai RHFE-1004FA Installation manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 44
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Owner’s Operation and Installation Manual for the
ES38 (RHFE-1004RFA)
Energysaver
Gas Direct Vent Wall Furnace
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Table of Contents ........... 2
Safety Information .......... 3
Operating Instructions .... 6
Care and Maintenance ... 10
Fault Codes .................... 12
Installation Instructions ... 14
Parts List ........................ 32
Consumer Support ......... 42
Register your product at www.rinnairegistration.com
or call 1-866-RINNAI1 (746-6241)
Przeglądanie stron 0
1 2 3 4 5 6 ... 43 44

Podsumowanie treści

Strona 1 - ES38 (RHFE-1004RFA)

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GA

Strona 2 - Table of Contents

10 Rinnai Corporation ES38 Manual Care and Maintenance Filters Dirty filters reduce the air flow and the appliance’s ability

Strona 3 - Consumer Safety Information

Rinnai Corporation ES38 Manual 11 Before Making a Service Call Before making a service call please check the following: At Igni

Strona 4 - Specifications

12 Rinnai Corporation ES38 Manual Fault Codes If there is a malfunction the appliance may shut down as a safety precaution a

Strona 5

Rinnai Corporation ES38 Manual 13 Troubleshooting ProblemRemedyCauseNot Plugged InPower Failure(Initial Installation)Air In

Strona 6 - Operating Instructions

14 Rinnai Corporation ES38 Manual Installation Instructions • A qualified service technician should install the appliance and inspect it before u

Strona 7

Rinnai Corporation ES38 Manual 15 Gas Connection • The gas supply line shall be gas tight, sized and so installed as to pro

Strona 8

16 Rinnai Corporation ES38 Manual Flue Terminal Clearances XVAIR SUPPLY INLET VENT TERMINAL AREA WHERE TERMINAL IS NOT PERMI

Strona 9

Rinnai Corporation ES38 Manual 17 Flue Terminal Clearances 1 A vent shall not terminate directly above a sidewalk or paved d

Strona 10 - CAUTION

18 Rinnai Corporation ES38 Manual Dimensions inches (mm) 14 1/16" (357.5)12 7/16" (316)13" (330)7 7/8" (

Strona 11

Rinnai Corporation ES38 Manual 19 Installation Parts The following items are included with the appliance: “A” Vent Kit, FOT-

Strona 12

2 Rinnai Corporation ES38 Manual This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile ho

Strona 13

20 Rinnai Corporation ES38 Manual Drilling Flue Hole Ensure that there are no gas or water lines, or electrical circuits in th

Strona 14 - Installation Instructions

Rinnai Corporation ES38 Manual 21 Flue Manifold Installation 1. Disassemble the flue manifold The flue consists of 3 parts

Strona 15 - WARNING

22 Rinnai Corporation ES38 Manual Flue Manifold Installation 6. Lock the ties Pulling hard on the left and right hand ties,

Strona 16

Rinnai Corporation ES38 Manual 23 Extension Kit Installation If necessary, extension kits are available to extend the exhaus

Strona 17

24 Rinnai Corporation ES38 Manual Clearances exhaust pipe to combustibles 1 inch (25.4 mm) exhaust pipe to non-combustibles zero Extension Kit

Strona 18

Rinnai Corporation ES38 Manual 25 Extension Kit Installation Item Description Part No. FOT-102 FOT-103 FOT-114 FOT-115 1

Strona 19

26 Rinnai Corporation ES38 Manual Connecting the Appliance 1. Attach flue adapter to the flue manifold with pipe stopper S. 2

Strona 20 - 3 1/8"

Rinnai Corporation ES38 Manual 27 Operating Instructions FOR YOUR SAFETY READ BEFORE OPERATING WARNING If you do not f

Strona 21

28 Rinnai Corporation ES38 Manual Cut-Away Diagram

Strona 22

Rinnai Corporation ES38 Manual 29 Wiring Diagram If any of the original wire as supplied with the appliance must be replace

Strona 23

Rinnai Corporation ES38 Manual 3 WARNING CAUTION Safety Behavior and Practices • Do not block the warm air dischar

Strona 24

30 Rinnai Corporation ES38 Manual Ladder Diagram

Strona 25

Rinnai Corporation ES38 Manual 31 Parts List For replacement parts call Rinnai at 1-800-621-9419.

Strona 26

32 Rinnai Corporation ES38 Manual Parts List For replacement parts call Rinnai at 1-800-621-9419.

Strona 27 - Manual Valve

Rinnai Corporation ES38 Manual 33 Parts List For replacement parts call Rinnai at 1-800-621-9419.

Strona 28

34 Rinnai Corporation ES38 Manual Parts List For replacement parts call Rinnai at 1-800-621-9419.

Strona 29

Rinnai Corporation ES38 Manual 35 Parts List For replacement parts call Rinnai at 1-800-621-9419.

Strona 30

36 Rinnai Corporation ES38 Manual Parts List For replacement parts call Rinnai at 1-800-621-9419.

Strona 31

Rinnai Corporation ES38 Manual 37 Parts List For replacement parts call Rinnai at 1-800-621-9419.

Strona 32

38 Rinnai Corporation ES38 Manual Parts List ITEM PART NUMBER QTY 1004RFA Beige 1004FA-W White 001 1001F-073-9 SIDE PA

Strona 33

Rinnai Corporation ES38 Manual 39 Parts List ITEM PART NUMBER QTY 1004RFA Beige 1004FA-W White 112 RHF250-076 AIR SH

Strona 34

4 Rinnai Corporation ES38 Manual Application For manufactured home (USA only) or mobile home or residential installation convertible for use with

Strona 35

40 Rinnai Corporation ES38 Manual Parts List ITEM PART NUMBER QTY 1004RFA Beige 1004FA-W White 181 304F-9112 CAP 1 1

Strona 36

Rinnai Corporation ES38 Manual 41 Parts List ITEM PART NUMBER QTY 1004RFA Beige 1004FA-W White 800 CP-74167-28 RATIN

Strona 37

42 Rinnai Corporation ES38 Manual Consumer Support Warranty Information Limited Warranty Gas Direct Ve

Strona 38

Rinnai Corporation ES38 Manual 43 Limited Warranty - continued Replacement of the product may be authorized by Rinnai only. R

Strona 39

Rinnai’s other fine products Rinnai America Corporation 103 International Drive Peachtree City, GA 30269 TOLL FREE: 1-800-621-9419 www.rinnai.us © 2

Strona 40

Rinnai Corporation ES38 Manual 5 Features • Restarts automatically when ignition or combustion fails. • Clean Heating

Strona 41

6 Rinnai Corporation ES38 Manual Getting to know your new heating appliance Operating Instructions

Strona 42 - Consumer Support

Rinnai Corporation ES38 Manual 7 Control Panel All buttons beep when operated. Set TempRoom TempEconomyTempControlFuncti

Strona 43

8 Rinnai Corporation ES38 Manual Operating the Heater Turning the heater ON When you press and release the ON/OFF button, the

Strona 44 - Rinnai’s other fine products

Rinnai Corporation ES38 Manual 9 CAUTION Adjusting Air Flow Direction The vertical louvers may be adjusted to move the air flow more to the